BACNET & MODBUS.
CONNECTED HVAC SYSTEMS.
Engineered Temperature Solutions designs and supports BACnet and Modbus integrations for commercial buildings in Columbus, Ohio; connecting HVAC equipment and controls into a unified system that improves visibility, simplifies control, and optimizes performance.
What Is BACnet & Modbus Communication?
BACnet and Modbus are open communication protocols that allow HVAC equipment, controllers, and building systems to share data and work together as one coordinated network. Instead of operating as isolated components, chillers, boilers, air handlers, VAV boxes, meters, and sensors can be monitored and controlled through a centralized building automation system.
For commercial buildings, this connectivity is what enables real-time system visibility, smarter control strategies, remote diagnostics, and performance optimization across the entire HVAC infrastructure.
At Engineered Temperature Solutions, we design, install, and support BACnet and Modbus integrations that ensure your equipment speaks the same language — creating reliable, scalable, and serviceable control networks built for long-term operation.

Open-System Connectivity
BACnet and Modbus let equipment from different manufacturers communicate on one shared network, avoiding proprietary lock-ins and improving flexibility.
Centralized Visibility
All connected devices feed data into one control platform for real-time monitoring of temperatures, airflow, alarms, and system status.
Smarter Control Logic
Integrated communication supports coordinated strategies like staging, load sharing, and energy-saving control sequences.
Scalable for Growth
New equipment and control points can be added without rebuilding the system, making future expansions easier and more cost-effective.

Our Services
ETS delivers complete BACnet and Modbus integration to unify HVAC equipment and building controls.
🚩BACNET & MODBUS RED FLAGS
When Should You Consider BACnet or Modbus Integration?
Signs Your Building Needs Better System Connectivity:
-
HVAC equipment operating independently
-
Limited visibility into system data
-
Inconsistent alarms and alerts
-
Difficulty diagnosing performance issues
-
Manual overrides required to maintain comfort
Control and performance issues often stem from communication gaps between systems long before equipment failure becomes obvious.
Disconnected Systems
Equipment that can’t communicate can’t coordinate staging, scheduling, or load sharing.
Lack of System Visibility
Without shared data, operators lose insight into temperatures, airflow, and system health.
Unreliable Alarm Reporting
Improper integration leads to nuisance alarms or missed fault conditions.
Troubleshooting Delays
Missing trend data and device status slows diagnosis and increases downtime.
Manual Control Dependence
When automation fails, staff must override systems to keep spaces comfortable.

Every HVAC Need.
One Reliable Team.












ETS HVAC Insights
Go inside our commercial HVAC projects and discover how ETS helps Central Ohio businesses upgrade systems, solve problems, and improve building performance year-round.
Frequently Asked Questions
BACnet is an open communication protocol that allows HVAC equipment, controllers, and building systems to share data and operate under a unified building automation system.
Modbus is commonly used to connect equipment like VFDs, meters, boilers, and chillers so performance data can be monitored and controlled by a central system.
BACnet is designed specifically for building automation networks, while Modbus is a simpler protocol often used for device-level communication and equipment monitoring.
Yes, many buildings use both protocols, typically connected through gateways that allow data to pass between different system types and control platforms.
Common equipment includes rooftop units, chillers, boilers, VAV systems, air handlers, cooling towers, energy meters, exhaust systems, and VFDs.
Most modern building automation systems rely on BACnet, Modbus, or both to communicate with equipment and provide centralized monitoring and control.
Poor integration can lead to missing data, unreliable alarms, inefficient equipment operation, manual overrides, and delayed troubleshooting.
In many cases, yes. Gateways, controller upgrades, and network redesign can often bring legacy equipment into a modern BAS environment.
When systems communicate, controls can coordinate staging, airflow, temperature resets, scheduling, and demand-based operation to reduce unnecessary runtime.
Point mapping assigns data values from field devices to control system software so temperatures, pressures, airflow, and alarms can be monitored and controlled correctly.
Control networks should be reviewed regularly as part of preventive maintenance to catch communication errors, failed devices, and control sequence issues early.
Most remote monitoring platforms rely on BACnet, Modbus, or both to pull real-time data from equipment into cloud-based dashboards and alert systems.
Timelines depend on system size and complexity, but many integrations can be completed within days to a few weeks once design and access are approved.
Yes. ETS provides full-service BACnet and Modbus integration, including system design, installation, configuration, optimization, and long-term support.
Yes. ETS supports controls integration alongside HVAC repair, maintenance, and upgrades to ensure automation strategies match real equipment performance.
Need BACnet and Modbus service in Central Ohio? Request a quote or call (614) 289-8733 to get started.
Frequently asked questions